4-20mA Sensor Integration Installation
1 - Electrical Connections
Refer to IoT Pro Opening and Closing for instructions on opening the device to access its wiring connections.
IOTPRO Interface Board Preparation
The analogue inputs of the IOTPRO can be configured for either 4–20mA or 0–30VDC sensors.
Open the IOTPRO and locate the GPIO/Sensor Interface Board
For 4-20mA operation, verify that the resistor selection connections are closed for each analogue input in use, as shown below

IOTPRO Wiring
Refer to the wiring diagram below and complete the following steps:
Connect the sensor's 4-20mA output to AIN1 and/or AIN2, as required.
Power the 4-20mA sensor using an external power supply or, optionally, the 12–24VDC power input terminals on the IOTPRO Power Board, provided the supply meets the sensor's requirements.
If the sensor is powered by a separate external power supply, ensure that the sensor ground (GND) is connected to the IOTPRO ground (GND) to establish a common ground reference

2 - Mechanical Installation
Refer to IoT Pro Installation Options for different installation options. Wall anchors are recommended for most applications.
3 - System Commissioning
Device Setup
Using the IoT Pro Device Setup Mobile Application:
Set the Analogue Mode to 4-20mA for Analogue Channels 1 and/or 2, as required
Activate the IoT Pro device according to the communication network being used:
Platform Setup
Make sure that you have access to the IoT Pro Cloud Platform. Follow the Getting Started guide to familiarize yourself first.
Open the IoT Pro Dashboard Mobile Application and log in
Navigate to Assets and select Create Asset
Under Asset Name & Device:
Enter an Asset Name
Select Application:
4_IOTPRO-DigitalAnalogueSerialSelect Device: choose the device installed in the previous section
Assign the asset to a group, if required
Complete the Asset Information fields as required
Under Asset Images, use Take Photo to capture the required photos of the completed installation
Under Advanced Fields, configure the following:
Asset Type: Circuit
Invert Values: Disabled
Channel Setting: Channel 1
Click Create Asset
Open the IoT Pro Device Setup Mobile Application, reconnect to the installed device, and select Send Message to transmit a new reading
Return to the IoT Pro Dashboard Mobile Application and navigate to Live Map to view your Asset
Use the Analogue Dashboard to view the circuit's readings and trends