7_IOTPRO-Marine

Fields

Field Name

ID - HEX

Size in Bytes

Description

Data Type

Uplink/

Downlink/

Both

device_param_power_supply_voltage

0x0FA2

2

Battery Bank 1 Voltage

Unsigned Integer, Unit: mV

Uplink

telemetry_param_analogue_dc_channel_1

0x0FD2

2

Battery Bank 2 Voltage

Unsigned Integer, Unit: mV

Uplink

telemetry_param_analogue_dc_channel_2

0x0FD3

2

Battery Bank 3 Voltage

Unsigned Integer, Unit: mV

Uplink

telemetry_param_dry_contact_channel_1

0x0802

1

Water Ingress

Boolean (0: Alarm, 1: Normal)

Uplink

telemetry_param_dry_contact_channel_2

0x0803

1

AC Shore Power

Boolean (0: Alarm, 1: Normal)

Uplink

telemetry_param_latitude

0x1F57

4

Vehicle Latitude

Signed (/10000000)

Uplink

telemetry_param_longitude

0x1F58

4

Vehicle Longitude

Signed (/10000000)

Uplink

telemetry_param_speed

0x0FE1

2

Vehicle Speed

Unsigned Integer, Unit: km/h

Uplink

Example Packet

Packet (HEX)

0x36B20140E17D77FD5D0FAA00071F42685D16260FD230140FD312340802010803000FA240AF

ID1

0x36B2

IMEI

Value1

0x0140E17D77FD5D

352812193545565

ID2

0x0FAA

Application ID

Value2

0x0007

Marine

ID3

0x1F42

Event 1: UNIX Time

Value3

0x685D1626

1750930982

ID4

0x0FD2

Event 1: Analogue DC Channel 1

Value4

0x3014

12.308V

ID5

0x0FD3

Event 1: Analogue DC Channel 2

Value5

0x1234

4.660V

ID6

0x0802

Event 1: Dry Contact Channel 1

Value6

0x01

Closed

ID7

0x0803

Event 1: Dry Contact Channel 2

Value7

0x00

Open

ID8

0x0FA2

Event 1: Battery Bank 1 Voltage

Value8

0x40AF

16.559V