11_IOTPRO-DieselTank

Fields

Field Name

ID - HEX

Size in Bytes

Description

Data Type

Uplink/

Downlink/

Both

telemetry_param_temperature_channel_1

0x0FBF

2

Temperature from an External Probe

Signed Integer (/100), Unit: °C

Uplink

telemetry_param_pressure_mh2o_channel_1

0x0FD4

2

Pressure Reading in mH2O

Unsigned Integer (/100), Unit: mH2O

Uplink

Example Packet

Packet (HEX)

0x36B20140E17D77FD5D0FAA000B1F42685D16260FBFFFFD0FD400B00FA240AF1F42685D168D0FBFFFFB0FD400F30FA240AF

ID1

0x36B2

IMEI

Value1

0x0140E17D77FD5D

352812193545565

ID2

0x0FAA

Application ID

Value2

0x000B

Diesel Tank

ID3

0x1F42

Event 1: UNIX Time

Value3

0x685D1626

1750930982

ID4

0x0FBF

Event 1: Temperature

Value4

0xFFFD

-0.03°C

ID5

0x0FD4

Event 1: Pressure

Value5

0x00B0

1.76 mH2O

ID6

0x0FA2

Event 1: Power Supply Voltage

Value6

0x40AF

16.559V

ID7

0x1F42

Event 2: UNIX Time

Value7

0x685D168D

1750931085

ID8

0x0FBF

Event 2: Temperature

Value8

0xFFFB

-0.05°C

ID9

0x0FD4

Event 2: Pressure

Value9

0x00F3

2.43 mH2O

ID10

0x0FA2

Event 2: Power Supply Voltage

Value10

0x40AF

16.559V